Anybus X-gateway – DeviceNet Scanner - PROFINET-IO Device

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between DeviceNet and PROFINET-IO networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Scanner on the DeviceNet network and a Device on the PROFINET network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

$0.00
    Availability: In stock
    x-gateway-devm-prts
    Datasheet File download Downloads Technical Services
    AB7647

    Features and benefits

    • Fast copying of cyclic I/O data between the two networks (10-15 ms)
    • Proven and tested with all PLC manufacturers
    • Powerful Scanner interface eliminates the need for a PLC controller on the DeviceNet network
    • Supports up to a maximum of 512 bytes of Input and Output data in each direction
    • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
    • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
    • Optional control status information added to I/O data for diagnostic purposes
    • Robust stand-alone housing for use in harsh industrial environments
    • Global free technical support and consultancy

    DeviceNet Scanner/Master features

    An Anybus X-gateway with an integrated DeviceNet Scanner interface can be used when there is no existing DeviceNet controlling PLC.

    • DeviceNet CONFORMANCE TESTED™ by ODVA
    • DeviceNetNet Specification version: Communications Adapter profile 12
    • Supports up to 63 DeviceNet Adapter/Slaves
    • Max. 512 bytes of Input and 512 bytes of Output data
    • Optional Live List of the active status of the connected adapters
    • DeviceNet baudrate 125, 250, 500 kbit/s
    • Supports I/O Slave messaging: Bit strobe, Polling, Cyclic and COS
    • MacID node address setting via DIP switches
    • 1x 5-pin, 5.08 Phoenix plug connector

    PROFINET I/O Device/Slave interface 

    PROFINET IO Device/Slave settings can be made by importing the provided .GSDML file into engineering tool of the controlling PLC. 

    • Complete PROFINET-IO Soft-Real-Time (RT) communication
    • Max 512 bytes of Input and 512 bytes of Output data
    • Up to 64 slots / 1 sub slot
    • Cyclic data exchange (10 ms cycle time)
    • Acyclic Data exchange (Record Data Requests) 
    • Baud rate 100 Mbit/s
    • Integrated FTP server provides easy file management using standard FTP clients
    • Web server with dynamic data capability and Server Side Include (SSI) capability
    • Email client with dynamic data capability and Event-triggered email handling
    • TCP/IP Configuration via DCP (Discovery and Configuration Protocol)
    • PROFINET uplink configuration via web interface or .GSDML file
    • 1x RJ45 network connector

    TECHNICAL SPECIFICATIONS

    Dimensions (L•W•H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
    Weight 400g or 0,880 lbs
    Operating temperature -25 to +65 °C  or  -13 to +149 °F 
    Storage temperature -40 to +85 °C  or  -40 to +185 °F 
    Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
    Current consumption     max. 400mA (Typical 200mA)
    Enclosure material  Aluminium and plastic
    Installation position Vertical / Flat*
    Galvanic isolation YES, on both BUS/Ethernet side
    Mechanical rating IP20, NEMA rating 1
    Mounting DIN-rail (EN 50022 standard)
    I/O configuration via USB port with Anybus Configuration Manager software
    Certifications CE, CULUS, RoHS

    Ordering Information

    x-gateway-devm-prts

    ORDER CODE: AB7647

    INCLUDED COMPONENTS:
    - Quick start documentation
    - USB configuration cable
    - Configuration software available for download
    - Anybus OPC server software available for download
    - (Power supply not included)

    GUARANTEE:  3 years

    For purchasing instructions and terms and conditions, see: How to buy

    Related products

    Anybus X-gateway – DeviceNet Adapter - PROFINET-IO Device

    More information

    Learn more about the Anybus X-gateway

    • Anybus X-gateway
    • What you can do
    • Data exchange
    • Anybus OPC Server

    Configuration

    See how to configure the X-gateway

    • Configuration Manager

    Next Steps

    • View case studies

    CONTACT HMS

    How to buy

    Find a Local Distributor

    Make an enquiry

    extend-x-gateway

    X-gateway assistance

    Through HMS Technical Services, start-up assistance, on-site help and trainings are available.
      

    You can also have our team create your configuration.
    Read more

    Applications

    Industrial devices
    PLC manufacturers
    Industry solutions

    Technologies

    Industrial Ethernet
    Fieldbus and Serial
    Wireless and others
    Industrial IIoT

    Products

    Embedded
    Gateways
    Wireless

    Support

    Contact Support
    Product Support
    Product Returns

    Contact

    Make an enquiry
    How to Buy
    Find a Distributor
    Newsletter Sign-up

    About HMS

    News
    Events
    Case Studies

    Like us Follow us Watch us Join us Newsletter
    OUR BRANDS: Anybus Ixxat Ewon Intesis
    HMS
    Copyright © 2020 HMS Networks.
    Menu
    • Cookies
    • Privacy Policy
    • Terms of Use
    • Partner login

    We use cookies on this site to enhance your user experience

    By clicking any link on this page you are giving your consent for us to set cookies.

    I want to find out more Yes, I agree