Anybus X-gateway – DeviceNet Scanner - ControlNet Adapter

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between DeviceNet and ControlNet networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Scanner on DeviceNet network and an Adapter on the ControlNet network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

$0.00
    Availability: In stock
    x-gateway-cnts-devm
    Datasheet File download Downloads Technical Services

    Features and benefits

    • Fast copying of cyclic I/O data between two networks (10-15 ms)
    • Proven and tested with all PLC manufacturers
    • Supports up to a maximum of 512 bytes of Input and Output data in each direction
    • Powerful Scanner interface for DeviceNet eliminates the need for a PLC controller
    • Optional control and status information added to the I/O data for diagnostic purposes
    • Robust stand-alone housing for use in harsh industrial environments
    • Global free technical support and consultancy

    DeviceNet Scanner/Master features

    An Anybus X-gateway with an integrated DeviceNet Scanner interface can be used when there is no existing DeviceNet controlling PLC.

    • DeviceNet CONFORMANCE TESTED™ by ODVA
    • DeviceNetNet Specification version: Communications Adapter profile 12
    • Supports up to 63 DeviceNet Adapter/Slaves
    • Max. 512 bytes of Input and 512 bytes of Output data
    • Optional Live List of the active status of the connected adapters
    • DeviceNet baudrate 125, 250, 500 kbit/s
    • Supports I/O Slave messaging: Bit strobe, Polling, Cyclic and COS
    • MacID node address setting via DIP switches
    • 1x 5-pin, 5.08 Phoenix plug connector

    ControlNet Adapter features

    ControlNet Adapter settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.

    • ControlNet CONFORMANCE TESTED™ by ODVA
    • ControlNet Specification version: Communications Adapter profile 12
    • Max. 450 bytes of Input and 450 bytes of Output data
    • ControlNet baudrate 5 Mbit/s
    • Supports Polled & Bitstrobed, I/O Change-of-state / cyclic I/O
    • Supports media redundancy
    • MacID node address setting via DIP switch
    • Network Access Port (NAP)
    • ControlNet network configuration via .EDS file
    • Can be used with RG-6 quad shielded cable
    • 2x BNC network connectors

    TECHNICAL SPECIFICATIONS

    Dimensions (L•W•H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
    Weight 400g or 0,880 lbs
    Operating temperature -25 to +65 °C  or  -13 to +149 °F 
    Storage temperature -40 to +85 °C  or  -40 to +185 °F 
    Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
    Current consumption     max. 400mA (Typical 200mA)
    Enclosure material  Aluminium and plastic
    Installation position Vertical / Flat*
    Galvanic isolation YES, on both BUS/Ethernet side
    Mechanical rating IP20, NEMA rating 1
    Mounting DIN-rail (EN 50022 standard)
    I/O configuration via USB port with Anybus Configuration Manager software
    Certifications CE, CULUS, RoHS

    Ordering Information

    x-gateway-cnts-devs

    ORDER CODE: AB7812

    INCLUDED COMPONENTS:
    - Quick start documentation
    - USB configuration cable
    - Configuration software available for download
    - (Power supply not included)

    GUARANTEE:  3 years

    For purchasing instructions and terms and conditions, see: How to buy

    Related products

    Anybus X-gateway – ControlNet Adapter - DeviceNet Adapter

    More information

    Learn more about the Anybus X-gateway

    • Anybus X-gateway
    • What you can do
    • Data exchange
    • Anybus OPC Server

    Configuration

    See how to configure the X-gateway

    • Configuration Manager

    Next Steps

    • View case studies

    CONTACT HMS

    How to buy

    Find a Local Distributor

    Make an enquiry

    extend-x-gateway

    X-gateway assistance

    Through HMS Technical Services, start-up assistance, on-site help and trainings are available.
      

    You can also have our team create your configuration.
    Read more

    Applications

    Industrial devices
    PLC manufacturers
    Industry solutions

    Technologies

    Industrial Ethernet
    Fieldbus and Serial
    Wireless and others
    Industrial IIoT

    Products

    Embedded
    Gateways
    Wireless

    Support

    Contact Support
    Product Support
    Product Returns

    Contact

    Make an enquiry
    How to Buy
    Find a Distributor
    Newsletter Sign-up

    About HMS

    News
    Events
    Case Studies

    Like us Follow us Watch us Join us Newsletter
    OUR BRANDS: Anybus Ixxat Ewon Intesis
    HMS
    Copyright © 2020 HMS Networks.
    Menu
    • Cookies
    • Privacy Policy
    • Terms of Use
    • Partner login

    We use cookies on this site to enhance your user experience

    By clicking any link on this page you are giving your consent for us to set cookies.

    I want to find out more Yes, I agree