Anybus X-gateway – CC-Link Slave - Interbus FO Slave

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CC-Link and Interbus Fiber Optic networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

x-gateway-ccls-ibssfo

CC-Link Slave interface

CC-Link Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.

  • Complete CC-Link slave Version 1 and 2 functionality
  • CC-Link Conformance BAP-05027-B specification
  • Transparent CC-Link communication (Standard Mode)
  • PLC Profile compliant communication (PLC profile mode)
  • Max. 896 bits/128 words (368 bytes) of I/O data in each direction
  • Supports CC-Link baudrates 156 kbit/s – 10 Mbit/s
  • Up to 4 occupied stations
  • Up to 8 extension cycles (version 2 only)
  • CC-Link configuration via on-board switches or via .CSP file
  • 1x 5-pin, 5.08 Phoenix plug network connector

Interbus Fiber Optic Slave Interface

Interbus Slave address settings can are automatically detected by the controlling PLC.

  • Complete Interbus functionality according to EN 50170
  • Fiber Optic features FSMA standard connectors conforming to IEC874-2 and DIN47258
  • Based on OPC chipset with support for optical diagnostics
  • Transmission Media: Plastic fibre, core 180um, clad 1000um: HCS (glass) fibre, core 200um, clad 230 um
  • Max. 20 bytes of process data (512 bytes with PCP) in each direction
  • PCP V.2.0. (0, 1, 2, or 4 words)
  • Interbus baudrate 500 kbit/s – 2 Mbit/s
  • Automatic slave address detection by controlling PLC master
  • 1x HFBR-2505C and 1x HFBR-1505C Fiber Optic network connectors

TECHNICAL SPECIFICATIONS

Dimensions (L•W•H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight 400g or 0,880 lbs
Operating temperature -25 to +65 °C  or  -13 to +149 °F 
Storage temperature -40 to +85 °C  or  -40 to +185 °F 
Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption     max. 400mA (Typical 200mA)
Enclosure material  Aluminium and plastic
Installation position Vertical / Flat*
Galvanic isolation YES, on both BUS/Ethernet side
Mechanical rating IP20, NEMA rating 1
Mounting DIN-rail (EN 50022 standard)
I/O configuration via USB port with Anybus Configuration Manager software
Certifications CE, CULUSRoHS

Ordering information

Order Code  AB7892
Included components            

Gateway
Quick start documentation
USB configuration cable

Power supply not included

Configuration is available for download.

3 year guarantee. For purchasing instructions and terms and conditions, see: How to buy

    Related products

What you can do!

Connect any two industrial networks — Fieldbus, or Industrial Ethernet or connect to IT systems via MQTT or OPC UA.

Data exchange

Learn more about how the X-gateway exchanges I/O Data.

X-gateway assistance

Through HMS Technical Services, start-up assistance, on-site help and trainings are available.

Anybus X-gateway case studies

Click the button down below to read more about our case studies.