Anybus CompactCom B40

For both general or demanding high performance applications

The cutting-edge Anybus CompactCom 40-series is based on the award-winning Anybus NP40 network processor. It is especially suitable for both general purpose and for high-end applications with large I/O data transfer, fast network cycles and synchronization demands.

    • Combines major fieldbus networks with high performance real-time Industrial Ethernet
    • Common Ethernet brick allows you to download your chosen Ethernet protocol to the module
    • Fast data transfer: up to 1500 bytes of process data each way (latency 15µs)
    • Unique way of handling device profile integration (Drive, Motion, Semi, Others)
    • Safety-ready. Combine with the IXXAT SafeT100 for safety network integration
    • Uses network encryption technologies to keep your devices safe and secure
    Anybus-CompactCom-B40-Brick

    Anybus CompactCom B40 Brick - CANopen

    The Anybus CompactCom B40 for CANopen is a high-performance network interface in Brick format — ready-made with software and hardware to enable communication between your device and the CANopen network.

    ADD YOUR OWN CONNECTORS AND PERIPHERALS

    The B40 Brick gives you the flexibility to add your own connectors and network isolation. An alternative is to use the ready-made connector board from HMS. The B40 Brick is ideal for device manufacturers who are looking for a semi-integrated solution where connector flexibility, size and cost are key elements.

    ONE IN-DESIGN – ACCESS ALL NETWORKS

    By implementing the B40 Brick into your product line, you can get connected to other B40 supported networks simply by switching to another Anybus Brick.

    GET REAL-TIME CANOPEN COMMUNICATION

    The B40 Brick enables fast communication between your device and CANopen. With its fast data transfer and very low latency, its the perfect match for even the most demanding industrial applications.

    $0.00
      Availability: In stock

      Features and benefits

      • A ready-made CANopen connectivity solution
      • Flexibility to add your own connectors and peripherals to limit size and costs
      • Easy mounting to your host PCB design
      • Short in-design with free assistance from HMS ensures a fast time to market
      • CiA pre-certified for network compliance (enables faster network certification)
      • Fast data transfer: Up to 512 bytes of process data in each direction,
        Up to 1524 bytes of acyclic data
      • Event-based interface method enables easy access to input and output data at any time
      • Fast, event-based application hardware interfaces: 8/16-bit parallel and highspeed SPI. I/O (shift register interface) is also available.
      • Solid security: Mandatory software signatures prevent unauthorized software to be downloaded to the module. Furthermore, encryption is used to prevent illicit copying.

      CANopen Slave interface

      • Network Identity customization
      • EMCY support
      • CiA-301 version 4.2.0 compliant
      • Supports all standard baud rates
      • Automatic baud rate detection
      • Supports LSS
      • Up to 57343 ADIs can be accessed from the network as Manufacturer Specific Objects and profile specific objects.
      • Up to 64 TPDO’s & 64 RPDO’s (Corresponds to a total of 512 bytes of Process Data in each direction)
      • PDO mapping can be customized via network configuration tool or via application (IO assemblies)
      • Diagnostic support
      • Support for process data remap from the network
      • Heartbeat functionality supported (Node Guarding not supported)
      • Supports Expedited- and Segmented SDO Transfer (Block Transfer not supported)
      • Network cycle time down to 1 ms
      • Possible to implement profiles

      Technical specifications

      Dimensions  (L•W•H)
      36 x 36 x 8 mm or 1,41 x 1,41 x 0,31"
       
      Operating temperature -40 to +85 °C  or  -40 to +185 °F  
      Power requirements 3.3 VDC, +/- 0.15 VDC
       
      Application Interface
      8/16-bit parallel (30 ns access)
      High speed SPI, baudrate configurable up to 20 MHz
      I/O (shift register interface, cyclical update time 82 μs)
      UART (for backwards compatibility with 30-series, max 625kbps)
       
      Profile support Generic device  
      LED indicators Available via host connector - Indicates Module Status and Network Status.  
      Connectors No: Add your own connectors (D-sub, 5.08, M12) - YES: via B40 connector board  
      Galvanic isolation
      No: Add your own isolation - YES: via B40 connector board
       
      Mechanical rating IP20, NEMA rating 1  
      Mounting PCB fastening via B40 connector boards available from HMS  
      Certifications CE, CULUS, RoHS  

      Ordering information

      Purchasing instructions and terms and conditions:  How to buy

      ORDER CODE AB6683 - B40 CANopen Brick                     abcc-b40