Easy configuration gets your Anybus X-gateway online in no-time!

 

No programming skills are needed to set up the Anybus X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

 

x-gateway-cabinet

The configuration of the X-gateway is made using the “Anybus Configuration Manager X-gateway” which is included in the price (Windows™ Tool). You install this on your PC, and connect the included USB cable to the configuration port of the X-gateway. 

The Anybus Configuration Manager X-gateway software is also available under the "Files and Documentation" support section of this website.

The easy-to-use Anybus Configuration Manager X-gateway allows you to define the I/O data sizes on each network side and to define the data mapping and separation between cyclic I/O data and parameter data, where applicable.

Configuring a Slave/Slave combination

In this scenario, the configuration of the X-gateway is solely made via the Anybus Configuration Manager without need for any additional configuration tools. However, the X-gateway must be integrated into the Master/Scanner/Client configuration of the corresponding PLC. For this purpose HMS provides the necessary electronic data sheets ( .GSD, GSDML, .EDS, .CSP files ).

(For versions with a Lonworks or J1939 interface, an additional Configuration Tool is included free-of-charge from HMS.) 

HMS Academy - How to configure
VIDEO: eg. How to configure an X-gateway between PROFIBUS and DeviceNet

Configuring a Master/Slave combination

In this scenario, the configuration of the X-gateway is made in TWO steps. Firstly the amount of I/O and parameter data as well as the mapping of the data between the two networks is defined by using the Anybus Configuration Manager.

Secondly, the network Master/Scanner interface needs to be configured by using an appropriate Master configuration tool, such as the free and included Anybus NetTool™ (for PROFIBUS or DeviceNet setup) or your own existing software such RSLogix®  or Step7 / TIA portal.

HMS Academy - How to configure
VIDEO: eg. How to configure an X-gateway with EtherNet/IP Adapter and PROFIBUS Master

Configuring Ethernet IP address settings

If you have chosen an X-gateway with at least one Ethernet based interface ( CC-Link IE Field, EtherNet/IP, EtherCAT, Modbus TCP, or PROFINET ), this Ethernet based network interface needs to be configured regarding its IP address settings. For this purpose the X-gateway has an inbuilt webpage that allows easy definition of the Ethernet address and parameter settings.

In case that you do not know your current IP address settings, HMS provides the free software "Anybus-IP Config Tool" which can be downloaded from the "Files and Documentation" support section of this website.

More information

Learn more about the Anybus X-gateway

  • Passerelles X-Gateway Anybus
  • Ce que vous pouvez faire
  • Data exchange
  • Anybus OPC server
  • Case studies

Configuration

See how to configure the Anybus X-gateway

  • Configuration Manager

Applications

Appareils
Fabricants d’automates
Secteurs industriels

Technologie

Bus de Terrain/Série
Ethernet Industriel
Sans Fil/Autres

Produits

Produits embarqués
Passerelles
Sans fil

Support

Par produit
Support en ligne

Contact

Acheter
Restez connecté
Partenaires de systèmes

About HMS

Évènements

Partager Commenter Visionner Mettre en relation Infolettre
NOS MARQUES: Anybus Ixxat Ewon Intesis
HMS
Copyright © 2020 HMS Industrial Networks.
Menu
  • Cookies
  • Politique de confidentialité
  • Conditions d'utilisation
  • Partner login

Ce site utilise des cookies pour améliorer votre expérience utilisateur

En utilisant notre site web, vous acceptez l’utilisation des cookies.

En savoir plus Oui, j’accepte