Anybus X-gateway
The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.The Profibus DP/DPV1 slave interface is implemented according to the standard IEC61158 as a modular slave, supporting all standard functionality such as Watchdog, Sync and Freeze and diagnostics. Standard DP as well as DPV1 acyclic data services (Class1/Class2) are supported. The Profibus interface module is certified by the Profibus user organization and has proven conformance and interoperability with leading PLC´s, HMI´s etc. Profibus address is set via rotary switches 0-99.
The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc
| KEY FEATURES | |
![]() |
|
| Watchdog support | |
| Sync and Freeze | |
| Supports PA baud rate 45.45 kbit/s | |
| Uses up to 4 occupied stations on CC-Link - configurable size | |
| Uses the CC-Link PLC profile for data exchange | |
| Complete Profibus DP and DPV1 (Class1/Class2) slave functionality according to IEC 61158 | |
| Support for CC-Link version 2.0 with extended data |
| TECHNICAL SPECIFICATIONS | |
| Size: | 126 mm x 110 mm x 42 mm |
| Power Supply: | 24 VDC (±10%) |
| Temperature: | 0-65°C |
| Current Consump: | max 300 mA |
| I/O Input: | Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link) |
| I/O Output: | Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link) |
| Mech Rating: | IP20/Nema1 |
| Config Method: | Windows Hyper Terminal |
| UL certification: | E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4 |
| ATEX certification: | ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03 |
| Power supply connector: | 2-pole 5.08 mm Phoenix pluggable screw connector |
| Profibus baudrate: | 9600 bit/s - 12 Mbit/s autodetect |
| Profibus address: | Node address 0-99 |
| Profibus connector: | D-sub 9-pin female |
| Profibus config.: | Configured by Profibus Master via GSD file (provided by HMS) |
| CC-Link baudrate: | 156kbps to 10Mbps |
| CC-Link address: | Station 1-64 |
| CC-Link connector: | 5-pole 5.08 mm Phoenix pluggable screw connector |
| CC-Link config.: | Configured by CC Link Master via CSP Config file (provided by HMS) |
| Price Group: | A |
| Order Code: | AB7852 |